Dive into our dynamic, ever-growing library of peer-reviewed publications, posters, application notes, and presentations showcasing the full breadth and depth of Trajan microsampling technologies. Discover cutting-edge methods, compelling scientific breakthroughs, and real-world applications spanning a wide range of disciplines.  

Search results are matched to the publication record, including title, abstract, keywords, authors, and other indexed details. All search terms must appear in the record for it to be included in your results.

Collection Type
Clear
Results per page are limited to 10.

Application of Dried Plasma Spots, Obtained by Micro‐Sampling Device for the Analysis of Rigosertib by LC/MS/MS

Mount Sinai
2015

Purpose – Develop the method based on dried plasma spots (DPS) obtained by a micro‐sampling device to quantify rigosertib in mouse and human plasma using LC/MS/MS.

Advantages and Limitations of Microsampling, Hematocrit and MicroLC in DBS: Quantitative Bioanalytical Assays for Immunosuppressants, Warfarin and Methylphenidate in Whole Blood

Worldwide clinical trials
2015

This presentation examines advantages and limitations of microsampling, hematocrit and MicroLC in DBS, with a focus on quantitative bioanalytical assays for immunosuppressants, warfarin and methylphenidate in whole blood.

A Comparison of VAMS™ Technology versus Traditional DBS Sampling in a Ligand Binding Assay

Amgen
2015

This study compares VAMS technology with traditional dried-blood-spot sampling for a ligand-binding assay. VAMS reduced hematocrit-related effects and supported accurate, precise measurements across the evaluated storage conditions.

A Comparison of Conventional vs. Microsampling Methodologies for In Vivo Pharmacokinetic Studies in Rodents

Trajan
2015

This study compares conventional vs. microsampling methodologies for in vivo pharmacokinetic studies in rodents. The precise and hematocritindependent transfer of 10 μL whole blood from the blood retrieval sites evaluated (cardiac puncture and saphenous vein) make it possible to conduct full pharmacokinetic time-course profiles in a small number of animals, supporting the ethical use of rodents in research and development.

Evaluation of the Mitra Microsampling Device for In Vivo Pharmacokinetic Studies

Trajan
2015

This study evaluated Mitra microsampling for acetaminophen pharmacokinetic studies in rats. The workflow supported serial whole-blood sampling, reduced animal use, and produced pharmacokinetic results consistent with published data.

The Skin Microbiopsy

Li Lin
2015

This thesis describes the design, manufacture, and evaluation of a minimally invasive skin microbiopsy for molecular research. It reports sample yields, volunteer testing, targeted lesion sampling, and downstream molecular applications while identifying low-input analytical variability as an area for further work.

BRAF Wild-Type Melanoma in Situ Arising in a BRAF V600E Mutant Dysplastic Nevus

Tan, Jean-Marie; Lin, Lynlee L.; Lambie, Duncan; Flewell-Smith, Ross; Jagirdar, Kasturee; Schaider, Helmut; Sturm, Richard A.; Prow, Tarl W.; Soyer, H. Peter
JAMA Dermatology | 2015

Dermoscopy-targeted microbiopsy and sequencing were used to examine genetic heterogeneity within a melanoma in situ arising in a dysplastic nevus. The melanoma component was BRAF wild type, while the nevus contained both wild-type and BRAF V600E results, demonstrating spatially targeted molecular sampling.

Quantitative bioanalysis of paracetamol in rats using volumetric absorptive microsampling (VAMS)

Denniff, P.; Parry, S.; Dopson, W.; Spooner, N.
J Pharm Biomed Anal | 2015

Researchers validated a VAMS method for paracetamol measurement and used it in a rat toxicokinetic study. The method produced parameters comparable with conventional samples and simplified collection and analysis, although controlling blood flow was important to prevent overfilling the sampler.

Targeted LC-MS quantification of intact TAT-fusion therapeutics: a case study

Zhao, X.; Sun, J.; Sun, L.; Chen, J.; Cheng, Y.; Duan, X.
Bioanalysis | 2015

This study developed an LC-MS method for intact TAT-fusion therapeutics in biological samples. The workflow improved sensitivity and successfully quantified a model TAT-conjugated therapeutic in rat plasma.

A device for dried blood microsampling in quantitative bioanalysis: overcoming the issues associated blood hematocrit

Spooner, N.; Denniff, P.; Michielsen, L.; De Vries, R.; Ji, Q. C.; Arnold, M. E.; Woods, K.; Woolf, E. J.; Xu, Y.; Boutet, V.; Zane, P.; Kushon, S.; Rudge, J. B.
Bioanalysis | 2015

This cross-laboratory study evaluated a volumetric dried-blood sampler across a broad hematocrit range. Collected volume remained consistent between laboratories, supporting the device’s potential to overcome common DBS volume and hematocrit limitations.