<img alt="" src="https://secure.agile-company-365.com/781893.png" style="display:none;">

Microsampling Publications Library

Dive into our dynamic, ever-growing library of peer-reviewed publications, posters, application notes, and presentations showcasing the full breadth and depth of Trajan microsampling technologies. Discover cutting-edge methods, compelling scientific breakthroughs, and real-world applications spanning a wide range of disciplines.  

Search results are matched to the publication record, including title, abstract, keywords, authors, and other indexed details. All search terms must appear in the record for it to be included in your results.

Collection Type
Clear
Results per page are limited to 10.

Evaluation of oral fluid microsampling as a urine surrogate matrix in substance use disorder care: clinical applicability and analytical performance

Thiebot, Pauline; Clergue Duval, Virgile; Djaker, Neila; Kononov, Alexandre; Schiestel, Thomas; Vorspan, Florence; Auzeil, Nicolas; Labat, Laurence
Clinical Toxicology | 2026

This clinical study evaluated volumetric absorptive oral-fluid microsampling as an alternative to urine testing in substance-use-disorder care. Paired testing showed high agreement for most analytes and improved patient acceptability, while matrix-specific detection windows and turnaround times remained limitations.

Multi-Matrix LC-MS/MS Validation of Methotrexate Polyglutamates: Comparison of VAMS, DBS, and Conventional Blood Sampling in Rheumatoid Arthritis

Kocur, A.; Kajfasz, M.; Mikulska, A.; Michalczuk, P.; Kwiatkowska, B.; Pawinski, T.
Int J Mol Sci | 2026

This study validated LC-MS/MS measurement of methotrexate polyglutamates across conventional blood matrices, DBS, and VAMS in rheumatoid arthritis. VAMS and DBS produced closely comparable capillary-sample results, although matrix-specific differences must be considered when relating them to red-blood-cell measurements.

Analytical validation of a dried blood microsampling method to measure androstenedione, 17α‑hydroxyprogesterone, and 11‑ketotestosterone for congenital adrenal hyperplasia monitoring

De Baets, Hanna; Reyns, Tim; Mazzarino, Monica; Fiers, Tom; Van Eenoo, Peter; Stove, Christophe P.
Talanta | 2026

Researchers validated LC-MS/MS measurement of three adrenal steroids in plasma, blood, and 20 µL VAMS samples for congenital adrenal hyperplasia monitoring. VAMS performance was accurate and precise across hematocrit and storage conditions, supporting future home-based monitoring.

Liquid Chromatographic Methods for Microsampling in Sports Drug Monitoring: Progress in DBS and VAMS

Zhang, Chunli
Biomedical chromatography : BMC | 2026

This review evaluates chromatographic and mass-spectrometric methods using DBS and VAMS for sports drug monitoring. It summarizes analytical applications and highlights remaining barriers involving detection windows, device comparability, sample preparation, stability, and regulatory acceptance.

Simultaneous quantification of linezolid and its metabolites (PNU-142300 and PNU-142586) in oral fluid and capillary blood by UPLC-MS/MS: method validation and clinical application using non-invasive sampling techniques

Gonzalez-Berdullas, P.; Cajade-Pascual, F.; Hermelo-Vidal, G.; Fernandez-Castro, I.; Molinos-Castro, S.; Bandin-Vilar, E.; Roca-Sanchez, R. M.; Vazquez-Agra, N.; Caeiro, J. R.; Zarra-Ferro, I.; Lendoiro, E.; Fernandez-Ferreiro, A.; Mondelo-Garcia, C.
J Transl Med | 2026

Researchers validated UPLC-MS/MS measurement of linezolid and its metabolites in oral fluid and capillary blood collected by VAMS. Linezolid correlated strongly with plasma in both matrices, while metabolite monitoring still requires matrix-specific correction and further clinical validation.

Volumetric Absorptive Microsampling (VAMS) N-Desmethyltamoxifen Analysis

Smolecule
2026

This application note discusses VAMS for therapeutic drug monitoring of tamoxifen metabolites, including N-desmethyltamoxifen and endoxifen. It highlights small-volume collection, room-temperature stability, and reduced dependence on conventional plasma sampling.

The Mitra Microsampling User Guide

Trajan
2026

This user guide summarizes best practices for research using Mitra devices with VAMS technology. It covers initial method-development decisions, dried-matrix handling, ambient shipping, storage, and sample collection.

Automated RNA Purification from Blood on a Mitra® Device with the Maxwell® RSC simplyRNA Blood Kit

Promega
2026

This application note provides a workflow for purifying RNA from whole blood collected on 10, 20, or 30 µL VAMS tips in a Mitra device using the Maxwell RSC simplyRNA Blood Kit and Maxwell RSC Instrument.

Tolerability and Feasibility of Minimally Invasive Canine Skin Sampling: Excellent Tolerability Meets Transcriptomic Challenges

Herrmann, I.; Mamo, L. B.; Dickey, A. N.
Vet Dermatol | 2026

This veterinary study compared microbiopsy, skin scraping, and tape stripping for minimally invasive skin sampling in dogs. All methods were feasible and well tolerated, but RNA yield, integrity, and contamination limited reliable downstream transcriptomic analysis.

Where are we after 15 years of minimally invasive skin sampling? A fit-for-purpose review of microbiopsy research from concept to the clinic.

Yamada, M.; Dev, V.; Nobel, M. E.; Pearson, F. E.; Layton, A.; Prow, T.
F1000Res | 2026

This review compares minimally invasive skin-sampling methods through a fit-for-purpose framework and uses microbiopsy development as a translational case study. It concludes that microbiopsy can complement other approaches when subsurface material, spatial precision, or repeat sampling is important, but is not a universal replacement for conventional biopsy.

customer support services

Microsampling and Microbiopsy specialists are available to provide expert support for the success of your project. 

remote-virtual-decentralized-clinical-trials

get started 

Let's begin with an initial customer consultation. Please contact us to proceed.