Dive into our dynamic, ever-growing library of peer-reviewed publications, posters, application notes, and presentations showcasing the full breadth and depth of Trajan microsampling technologies. Discover cutting-edge methods, compelling scientific breakthroughs, and real-world applications spanning a wide range of disciplines.  

Search results are matched to the publication record, including title, abstract, keywords, authors, and other indexed details. All search terms must appear in the record for it to be included in your results.

Collection Type
Clear
Results per page are limited to 10.

Measurement of Centanafadine Concentrations in a Pharmacokinetic Trial: Comparison of Traditional Venipuncture Versus Blood Microsampling

Roth, S. E.; Westcott-Baker, L.; Wang, Y.; Chung, C.
Clin Transl Sci | 2026

This pharmacokinetic study compared traditional venipuncture with self-collected blood microsamples for measuring centanafadine. The validated microsampling method showed concordance with venous sampling and supported feasibility of at-home PK sample collection.

Thiamine status in Belgian adults assessed by volumetric absorptive microsampling: a nation-wide cross-sectional survey

Heughebaert, L.; Berger, N.; Moyersoen, I.; Stove, C. P.
Am J Clin Nutr | 2026

This nationwide Belgian survey used at-home VAMS to assess thiamine biomarker status in adults. The study found that biomarker results identified thiamine insufficiency not apparent from intake data, supporting VAMS for large-scale nutritional assessment.

Volumetric absorptive microsampling and conductive vial electromembrane extraction for the analysis of pharmaceuticals in whole blood

Reguli, A.; Dowlatshah, S.; Hansen, F. A.; Sterbova-Kovarikova, P.; Pedersen-Bjergaard, S.
Talanta | 2026

This study evaluated conductive vial electromembrane extraction as a cleanup method for pharmaceuticals collected on VAMS tips. The optimized workflow improved reproducibility and reduced matrix effects, supporting potential use in routine bioanalytical applications.

Expanding the detection of anabolic steroid doping: alternative sample matrices and techniques

LANGER, Tobias
2025

This thesis examines expanding the detection of anabolic steroid doping, with a focus on alternative sample matrices and techniques. All four laboratories were able to detect the spiked testosterone esters in both serum and DBS samples, demonstrating their capabilities for the analysis of these substances and supporting the strategies for a harmonised approach.

Environmental Exposure to Metals in Children and Their Effects on Autism Spectrum Disorder

Oludesola Ogunesan
2025

This thesis examines environmental exposure to metals in children and their effects on autism spectrum disorder. Together, these studies provide a comprehensive understanding of how environmental exposures, spatial disparities, and community engagement intersect to influence ASD outcomes in Alabama.

Wide-targeted Metabolomics in Dried Blood Spots

Harald Schoeny, Bruno Stelzer, Gunda Koellensperger
LCGC Supplements | 2025

This study examines wide-targeted metabolomics in dried blood spots. Stability testing confirmed that most metabolites remain reliable in DBS samples stored at room temperature for up to three weeks.

Volumetric absorptive microsampling for in vitro metabolism of the recent synthetic cannabinoid receptor agonist 5F-PB-22

Protti, Michele; Mandrioli, Roberto; Noreen, Sobia; Leone, Antonio; Sardella, Roccaldo; González-Rodríguez, Jose; Mercolini, Laura
Microchemical Journal | 2025

This study examines volumetric absorptive microsampling for in vitro metabolism of the recent synthetic cannabinoid receptor agonist 5F-PB-22.

Use of blood micro-samples in forensic thanatology

Bertrand-Ndoye, M.; Girard, H.; Hakim, F.; Gish, A.; Ghoul, C.; Delannoy, Y.; Scanvion, Q.; Hedouin, V.; Gaulier, J. M.
Forensic Sci Int | 2025

This work examines the use of blood micro-samples in forensic thanatology. Heroin, several benzodiazepines, and cocaine showed excellent stability on DBS, while they degraded or disappeared in conventional tubes.

Toward minimally invasive metabolomics: GC-MS metabolic fingerprints of dried blood microsamples in comparison to plasma

Marques de Sa, E. Silva D.; Thaitumu, M.; Virgiliou, C.; Tiganouria, A.; Rey-Stolle, F.; Avgerinou, G.; Petridou, A.; Mougios, V.; Theodoridis, G.; Gika, H.
Analyst | 2025

This study examines toward minimally invasive metabolomics, with a focus on GC-MS metabolic fingerprints of dried blood microsamples in comparison to plasma. Overall, the results suggest that BmuS is a viable alternative for untargeted blood metabolomics, providing comparable information.

Recent trends in microsampling and reduced-volume sample preparation procedures

Perrucci, Miryam; Ricci, Erika Maria; Locatelli, Marcello; Ali, Imran; Mansour, Fotou R.; Kabir, Abuzar; Ulusoy, Halil I.
Advances in Sample Preparation | 2025

This study examines recent trends in microsampling and reduced-volume sample preparation procedures. Techniques such as Solid-Phase Microextraction (SPME) and Volumetric Absorptive Microsampling (VAMS) are being explored as promising tools for obtaining dried biological matrices, such as blood, urine, and saliva offering potential improvements over traditional methods like Dried Blood Spotting (DBS).