<img alt="" src="https://secure.agile-company-365.com/781893.png" style="display:none;">

Microsampling Publications Library

Dive into our dynamic, ever-growing library of peer-reviewed publications, posters, application notes, and presentations showcasing the full breadth and depth of Trajan microsampling technologies. Discover cutting-edge methods, compelling scientific breakthroughs, and real-world applications spanning a wide range of disciplines.  

Search results are matched to the publication record, including title, abstract, keywords, authors, and other indexed details. All search terms must appear in the record for it to be included in your results.

Collection Type
Clear
Results per page are limited to 10.

Comparison of nanofluidic and ultra-high performance liquid chromatography-tandem mass spectrometry for high sensitive pharmacokinetic studies of estrogens starting from whole blood microsampling

Nys, G.; Cobraiville, G.; Kok, M. G. M.; Wera, O.; Servais, A. C.; Fillet, M.
J Chromatogr A | 2017

Researchers compared nanofluidic LC-MS/MS with conventional UHPLC-MS/MS for measuring estradiol and estetrol after VAMS collection. The miniaturized LC-chip approach achieved substantially greater sensitivity while enabling whole-blood microsampling for small-animal pharmacokinetic studies.

Assessing Volumetric Absorptive Microsampling Coupled with Stable Isotope Dilution Assay and Liquid Chromatography-Tandem Mass Spectrometry as Potential Diagnostic Tool for Whole Blood 5-Methyltetrahydrofolic Acid

Kopp, M.; Rychlik, M.
Front Nutr | 2017

Researchers evaluated VAMS with stable-isotope dilution LC-MS/MS for measuring whole-blood 5-methyltetrahydrofolate. The minimized collection approach was feasible for folate assessment and could support more efficient newborn or population screening after further optimization of background interference and automation.

Application of volumetric absorptive microsampling for robust, high-throughput mass spectrometric quantification of circulating protein biomarkers

van den Broek, I.; Fu, Q.; Kushon, S.; Kowalski, M. P.; Millis, K.; Percy, A.; Holewinski, R. J.; Venkatraman, V.; Van Eyk, J. E.
Clin Mass Spectrom | 2017

Researchers developed an automated, high-throughput VAMS workflow for mass-spectrometric quantification of circulating protein biomarkers. Strong recovery, reproducibility, and long-term storage performance support its use for remote and personalized biomarker monitoring.

Volumetric absorptive microsampling at home as an alternative tool for the monitoring of HbA1c in diabetes patients

Verougstraete, N.; Lapauw, B.; Van Aken, S.; Delanghe, J.; Stove, C.; Stove, V.
Clin Chem Lab Med | 2017

This study evaluated home-collected VAMS and dried blood spot samples for HbA1c monitoring in adults and children with diabetes. Results from dried microsamples showed poor agreement with hospital-based measurements, indicating that the tested workflow was not reliable for routine HbA1c monitoring.

Volumetric absorptive microsampling combined with impact-assisted extraction for hematocrit effect free assays

Youhnovski, N.; Mayrand-Provencher, L.; Berube, E. R.; Plomley, J.; Montpetit, H.; Furtado, M.; Keyhani, A.
Bioanalysis | 2017

This study combined VAMS with bead-based impact-assisted extraction for naproxen and ritonavir measurement. The extraction procedure produced quantitative recovery without hematocrit-related bias and met precision, accuracy, and matrix-effect criteria.

Evaluation of sample extraction methods for minimizing hematocrit effect on whole blood analysis with volumetric absorptive microsampling

Ye, Z.; Gao, H.
Bioanalysis | 2017

This study evaluated extraction solvents for VAMS samples across a wide hematocrit range. A methanol-acetonitrile workflow improved and stabilized analyte recovery while minimizing hematocrit-related effects.

Sponge Spray-Reaching New Dimensions of Direct Sampling and Analysis by MS

Hecht, M.; Evard, H.; Takkis, K.; Veigure, R. T.; Aro, R.; Lohmus, R.; Herodes, K.; Leito, I.; Kipper, K.
Anal Chem | 2017

This study introduced sponge-spray mass spectrometry for direct analysis from volumetric microsampling tips. The approach quantified penicillin G in plasma and urine with minimal sample preparation, demonstrating a rapid alternative for clinical analysis.

Pre-analytic evaluation of volumetric absorptive microsampling and integration in a mass spectrometry-based metabolomics workflow

Volani, C.; Caprioli, G.; Calderisi, G.; Sigurdsson, B. B.; Rainer, J.; Gentilini, I.; Hicks, A. A.; Pramstaller, P. P.; Weiss, G.; Smarason, S. V.; Paglia, G.
Anal Bioanal Chem | 2017

This study integrated VAMS into an untargeted mass-spectrometry metabolomics workflow and evaluated extraction and storage conditions. Acetonitrile-water extraction improved metabolite recovery, while frozen storage best preserved the dried-blood metabolome.

Volumetric absorptive microsampling integrated into an automated bottom-up proteomics workflow

Cedar-Sinai
2016

This presentation integrates protein extraction from Mitra tips into an automated bottom-up proteomics workflow. Protein recovery and digestion were reproducible, with further work focused on stability, cleanup, and clinical applications.

Volumetric Absorptive Micro Sampler (VAMS or Mitra) in Clinical Diagnostic: -Therapeutic Drug Monitoring and Diagnostic Biomarkers

Exagen diagnostics
2016

This presentation evaluates Mitra VAMS sampling for therapeutic drug monitoring and diagnostic biomarkers. It describes methotrexate and rheumatoid-factor assay development and supports capillary microsamples as a potential alternative to venous whole blood.

customer support services

Microsampling and Microbiopsy specialists are available to provide expert support for the success of your project. 

remote-virtual-decentralized-clinical-trials

get started 

Let's begin with an initial customer consultation. Please contact us to proceed.