<img alt="" src="https://secure.agile-company-365.com/781893.png" style="display:none;">

Microsampling Publications Library

Dive into our dynamic, ever-growing library of peer-reviewed publications, posters, application notes, and presentations showcasing the full breadth and depth of Trajan microsampling technologies. Discover cutting-edge methods, compelling scientific breakthroughs, and real-world applications spanning a wide range of disciplines.  

Search results are matched to the publication record, including title, abstract, keywords, authors, and other indexed details. All search terms must appear in the record for it to be included in your results.

Collection Type
Clear
Results per page are limited to 10.

A Validated Volumetric Absorptive Microsampling-Liquid Chromatography Tandem Mass Spectrometry Method to Quantify Doxycycline Levels in Urine: An Application to Monitor the Malaria Chemoprophylaxis Compliance

Penot, M.; Linard, C.; Taudon, N.
J Anal Methods Chem | 2020

Researchers validated a VAMS-based LC-MS/MS method for measuring doxycycline in urine to monitor malaria chemoprophylaxis adherence. Results agreed with directly diluted samples, supporting VAMS as a practical field alternative for compliance assessment.

Volumetric Absorptive Microsampling (VAMS) technology for IGF-1 quantification by automated chemiluminescent immunoassay in dried blood

Marchand, A.; Roulland, I.; Semence, F.; Audran, M.
Growth Horm IGF Res | 2020

This study evaluated dried capillary VAMS samples for IGF-1 measurement using an automated chemiluminescent immunoassay. The approach was feasible, but lower values at high serum concentrations indicate that dedicated dried-blood reference ranges require further study.

Proteomic Profiling and Monitoring of Training Distress and Illness in University Swimmers During a 25-Week Competitive Season

Knab, A. M.; Nieman, D. C.; Zingaretti, L. M.; Groen, A. J.; Pugachev, A.
Front Physiol | 2020

This season-long study combined proteomic profiling with athlete-reported illness and training-distress measures in university swimmers. Immune-protein patterns helped distinguish the most stressful training periods, while athlete reports did not consistently align with coaches’ assessments.

A Volumetric Absorptive Microsampling Technique to Monitor Cannabidiol Levels in Epilepsy Patients

Dubois, S.; Marchese, F.; Pigliasco, F.; Barco, S.; Tripodi, G.; Lomonaco, T.; Lattanzi, S.; Russo, E.; Cangemi, G.; Striano, P.
Front Pharmacol | 2020

This proof-of-concept study compared VAMS capillary-blood cannabidiol measurements with conventional plasma results in patients with epilepsy. Concentrations were strongly correlated, supporting VAMS as a minimally invasive tool for personalized therapeutic monitoring.

Volumetric Absorptive Microsampling as a Sampling Alternative in Clinical Trials and Therapeutic Drug Monitoring During the COVID-19 Pandemic: A Review

Harahap, Y.; Diptasaadya, R.; Purwanto, D. J.
Drug Des Devel Ther | 2020

This review considers VAMS as an alternative sampling method for clinical trials and therapeutic drug monitoring during the COVID-19 pandemic. It highlights home collection, fixed-volume sampling, room-temperature shipment, low sample volume, and reduced hematocrit effects as practical advantages.

Volumetric absorptive microsampling and dried blood spot microsampling vs. conventional venous sampling for tacrolimus trough concentration monitoring

Veenhof, H.; Koster, R. A.; Junier, L. A. T.; Berger, S. P.; Bakker, S. J. L.; Touw, D. J.
Clin Chem Lab Med | 2020

This clinical comparison assessed VAMS, dried blood spot, and conventional venous sampling for tacrolimus trough monitoring in kidney-transplant patients. Dried blood spots showed stronger agreement with venous blood, while VAMS had more sample-quality problems and was not considered an equivalent replacement under the study conditions.

Development and validation of volumetric absorptive microsampling coupled with UHPLC-MS/MS for the analysis of gamma-hydroxybutyric acid in human blood

Mohamed, S.; Riva, R.; Moresco, M.; Plazzi, G.; Contin, M.
Biomed Chromatogr | 2020

This study developed and validated a VAMS–UHPLC-MS/MS method for gamma-hydroxybutyric acid in human blood. The assay met current validation guidelines and produced results comparable with a plasma-based method in a proof-of-concept patient sample.

Novel LC-MS/MS method for the determination of selumetinib (AZD6244) in whole blood collected with volumetric absorptive microsampling

Voggu, R. R.; Brus, T. S.; Barksdale, C. T.; Severin, P.; Hansen, P.; Chudnovskiy, R.; Thomas, E.; Bailey, C.
Bioanalysis | 2020

This study developed and validated an LC-MS/MS method for selumetinib in VAMS whole-blood samples. All validation criteria were met, and the drug remained stable under both ambient and frozen storage conditions.

Analysis of 14 drugs in dried blood microsamples in a single workflow using whole blood and serum calibrators

Vincze, I.; Rudge, J.; Vasarhelyi, B.; Karvaly, G. B.
Bioanalysis | 2020

This study evaluated a single workflow for measuring 14 drugs in dried blood using whole-blood and serum calibrators. Multiplexed testing was feasible, but performance varied by analyte and requires confirmation with clinical specimens.

Validation and clinical application of a volumetric absorptive microsampling method for 14 psychiatric drugs

Stern, M.; Giebels, M.; Fey, T.; Lubking, M.; Alferink, J.; Hempel, G.
Bioanalysis | 2020

This study developed and clinically validated a VAMS method for 14 antidepressants, antipsychotics, and active metabolites. Derived blood-to-plasma conversion factors supported use of the workflow in routine health care.

customer support services

Microsampling and Microbiopsy specialists are available to provide expert support for the success of your project. 

remote-virtual-decentralized-clinical-trials

get started 

Let's begin with an initial customer consultation. Please contact us to proceed.