Developing a Method for Quantifying Meropenem in Children-Volumetric Adsorptive Microsampling Versus Plasma Sampling
Researchers assessed whether whole-blood VAMS could support meropenem therapeutic drug monitoring in critically ill children. VAMS results could not be converted reliably to plasma concentrations, so the team instead validated a low-volume method using 50 µL of plasma.