An article by Michele Protti et al at the University of Bologna in Italy and other institutions, published in the September 2022 edition of Molecules, investigated the use of Mitra® devices with VAMS® technology for tryptophan (Trp) and related biomarkers. The paper is entitled “Volumetric Absorptive Microsampling (VAMS) for Targeted LC-MS/MS Determination of Tryptophan-Related Biomarkers.”
This pilot study successfully measured 24 metabolomic biomarkers from three key metabolic pathways. The authors concluded that this method – using VAMS extracts and LC-MS/MS – can be applied to analyze Trp metabolites and related biomarker levels to monitor disease states, perform mechanistic studies and investigate the outcomes of therapeutic interventions.
In recent years, omic biomarker research has exploded. The field of metabolomics has been particularly active. A 2020 review by Michael A Kiebish et al at BERG Health reported that PubMed had recorded an exponential growth in published metabolomic biomarker manuscripts. This is a major push forward compared to the previous decade in which fewer than 200 papers on metabolomic biomarkers were submitted for publication.
A significant increase was seen in 2019, when approximately 1,400 papers on metabolomics and/or metabolomic biomarkers were published. A similar trend was observed with regard to papers published on the combined topics of metabolomics and pharmaceuticals. Indeed, a recent online search of the word ‘metabolomics’ on www.clinicaltrials.gov delivered a result of 1,697 studies, of which 761 were listed as “not yet started” or “active”.
Metabolomics gives us a snapshot into the metabolic pathways within our cells and extracellular spaces, including contributions from the biome. Indeed, the same review by Michael A Kiebish et al reported that the human metabolic database, or HMDB, listed >25,000 metabolites in human blood. Understanding metabolic pathways and how they interact with disease can help to diagnose and prognose conditions. It is thought that metabolites may act as a barometer of an individual’s health prior to any disease onset.
Indeed, one family of metabolites that are of great interest to diagnosing and treating a number of conditions, such as neurodegenerative diseases and cancers, are related to metabolites found in tryptophan (Trp) related pathways. For example, one specific pathway that is of great interest to researchers is the kynurenine (Kyn) pathway (KP) of Trp degradation. Additionally, enzymes such as indoleamine-2,3-dioxygenase 1 and 2, as well as tryptophan-2,3-dioxygenase (TDO) are targets for therapies, with multiple compounds in clinical trials investigating a class called immune checkpoint inhibitors.
One of the key challenges for metabolomics research is sample collection, not only for ease of blood collection in clinical research or human trials but also in preclinical studies involving lab animals. Mice are often the lab animal of choice for blood sampling during in vivo studies conducted in preclinical research. However, taking blood samples from mice in an ethical way can be challenging, because mice typically only have about 1.5-2.8 mL of blood. This means that more mice may be needed in order to collect a sufficient number of blood samples required for gathering data. This presents a dilemma, since research labs strive to use as few animals as possible to complete their studies.
One solution to reducing animal usage in preclinical research has been to employ microsampling strategies. Less invasive and low-volume sampling tools such as dried blood spot (DBS) cards and Mitra devices with VAMS are key in helping to reduce the number of mice used in studies. Although DBS cards have been used for metabolomics studies and others, Protti et al decided to employ VAMS devices for the study reviewed here.
One reason was because devices based on volumetric absorptive microsampling can overcome several of the challenges of older dried blood spot technology. One such challenge is the hematocrit dependent volumetric spot spread bias. Therefore, the team embarked on a proof-of-concept study to evaluate VAMS for analysis of 24 tryptophan-related biomarkers.
Development of reliable and well-validated methods is critical for emerging omics. The conversion of volumetric microsampling approaches and highly sensitive analytical methodologies such as LC-MS/MS (as utilized in this study) opens the door for the personal health monitoring revolution. Indeed, Trajan microsampling devices have been used in a wide variety of omics studies, from measuring microRNA for biomarker research to targeted and untargeted proteomics and metabolomics.
Indeed, a recent untargeted proteomics paper identified more than 1,642 proteins from one 30 µL Mitra device, such is the power of modern LC-MS/MS methodologies and instrumentation. As discussed in another blog, the hemaPEN® microsampling device has been used to successfully measure metabolomic biomarkers in athletes during exercise and rest.
This article was summarized for our readers by James Rudge, PhD, Neoteryx Technical Director. This is curated content. To learn more about the important research outlined in this blog, visit the original article in Molecules.
For more information on how Neoteryx microsampling products from Trajan are benefiting omics researchers, please visit our Technical Resource Library and select ‘omics’ in the key topic field.
Image Credits: iStock, Neoteryx, Trajan