An article by Hugues Chanteux et al at UCB Biopharma Belgium and two other institutions published in the November 2023 edition of The AAPS Journal described the use of Mitra® microsampling devices based on VAMS® technology in several clinical trials for development of an anticonvulsant called padsevonil (PSL). Their paper was entitled “Clinical Bridging Studies and Modeling Approach for Implementation of a Patient Centric Sampling Technique in Padsevonil Clinical Development.”
From their work they were able to conclude that the approach used for bridging was considered adequate by the Food and Drug Administration (FDA) to support Mitra devices as the sole method for PK sampling in future clinical trials.
Traditionally, the gold standard biological matrix for measuring the concentration of drugs in blood is plasma. Plasma is the straw-colored liquid which remains when the cellular intact portion of blood (hematocrit, or HCT) is removed either by centrifugation or filtration.
One reason is that plasma is a less complex matrix, so there are less matrix interferences to mitigate when quantitating drug molecule concentrations. This is particularly important for LC-MS applications where matrix enhancement and suppression effects are commonly observed and need to be controlled.
Another reason is that protein free drugs in plasma are often what is available for peripheral cells to interact with, allowing pharmacological effects. As a result, it is useful to measure the change in free drug concentrations during pharmacokinetic studies.
Plasma is not without its drawbacks, however. First, a plasma assay does not take into account any partitioning that the drug has undertaken into the HCT. This is important with drugs that partition preferentially into the HCT where removal of the HCT will result in removal of a majority of the drug. There is a risk of underrepresenting the drug concentration in plasma-based drug studies.
Under these circumstances, measuring the drug concentration from blood which contains cells is vital to get a representative drug concentration. An example of such a class of drugs that associate primarily with the HCT are the calcineurin inhibiters, such as tacrolimus and cyclosporine.
For the vast majority of drugs, either the molecule partitions equally into the HCT, or partitioning favors the plasma fraction. This is why plasma has historically been the preferred matrix for measuring drug concentration levels for a range of drugs. Due to improvements in analytical technology, it is very possible to measure these drugs from whole blood, too.
However, if an assay has been initially validated in venous plasma, then clinical bridging needs to be conducted to understand what biases are seen when transitioning an assay to whole blood. Firstly, B:P partitioning can be dynamic. Under these circumstances, the partitioning can be concentration- and or time-dependent. Furthermore, drug concentrations may not be the same in the peripheral circulation compared to central circulation as sampled in venous blood.
Finally, the impact of anticoagulants needs to be taken into consideration when uncoagulated capillary blood is collected and compared to venous plasma harvested from stabilized blood.
As discussed in the paper summarized here, the team at UCB Biopharma in Belgium used Mitra devices based on VAMS technology in several clinical trial phases during drug development of the anticonvulsant Padsevonil (PSL). The Mitra devices offered their study cohorts convenient remote sampling by enabling collection of < 30 µL blood samples at home from a finger-prick. The remote samples could be collected by study cohorts themselves or with assistance from a friend or family member.
The Mitra devices delivered dried blood samples for analysis, which was a benefit because dried blood is often considered safer and more stable than wet blood. For this reason, dried blood samples can typically be sent in the regular mail to laboratories for testing, which negates the need for cold chain shipping and storage. These benefits make remote, volumetric absorptive microsampling ideal for large multi-center clinical trials.
It was critical for the UCB Biopharma team to thoroughly understand the blood to plasma partitioning kinetics of the drug by conducting extensive clinical bridging. From this data they were able to develop an algorithm to compensate for the dynamic B:P partitioning that they observed.
Six clinical trials were conducted to understand the PK of PSL where analysis of the relationship between Mitra samples and venous plasma was investigated. Four of these trials were employed for method development and the final two (which included a phase 2 trial) for method validation.
The paper highlights the importance of clinical bridging to correlate between blood samples collected from a finger-prick and venous blood drawn from a vein in the arm.
The work summarized here shows the successful implementation of using dried blood samples in a drug development program where over 2,500 paired samples were successfully collected. The clinical bridging data demonstrated that it was possible to use just dried blood samples for part of the study. The work also showed that both samples collected in clinic and remotely could be effectively correlated.
Additionally, this study highlighted the importance of the sampling site (i.e., fingertip vs. arm) and how the drug concentration can change between venous blood and capillary blood collected from a fingerpick, especially in the early stages of dosing. Understanding this phenomenon and mitigating it using statistical models from clinical bridging increases the likelihood of successful use of dried blood samples in future remote or hybrid clinical trials.
Readers are encouraged to refer to an excellent paper by Rowland and Emmons, which discusses in depth the impact of using dried blood in PK studies (a point that was also highlighted by the authors of this study.)
This article was summarized for our readers by James Rudge, PhD, Neoteryx Microsampling Technical Director, Trajan. This is curated content. To learn more about the important research outlined in this blog, visit the original article in The AAPS Journal.
Image Credits: Trajan, Neoteryx, iStock